Allen-Bradley Logix — EtherNet/IP by tag name
Connect to Rockwell Logix controllers with the tag names in the PLC, without writing an address table. Structures, arrays and program tags are read and written; the tag list comes from the device.
| Tag | Address | Value | Quality |
|---|---|---|---|
| Line_Speed | Line_Speed | 42.5 | |
| Motor1_Run | Motor[1].Running | 1 | |
| Part_Count | Program:Main.PartCount | 18240 | |
| Alarm_Bit | AlarmWord.3 | 0 | |
| Recipe | RecipeName | BOX-200 |
The MergenHub interface — tag-name access on a CompactLogix controller: structure member, program tag, DINT bit and STRING.
Logix and EtherNet/IP
ControlLogix, CompactLogix and GuardLogix controllers keep their data in named tags and offer symbolic access through the CIP protocol over EtherNet/IP. MergenHub reaches those tags directly by name.
Where is it used?
Machine and line control in automotive, food, pharma, packaging and water treatment plants. Sites with Rockwell and other PLC brands side by side are brought under one SCADA.
First live data in four steps
Connects to ControlLogix, CompactLogix, GuardLogix and Micro800 by tag name over EtherNet/IP (CIP); no extra software such as RSLinx is needed.
- 01
Add a channel
Choose the Allen-Bradley ControlLogix Ethernet driver with Add Channel. The same driver also serves CompactLogix, GuardLogix and Micro800.
- 02
Add a device
Add Device and pick the Model; the ID is the IP, backplane and CPU slot:
192.168.1.10,1,0. On CompactLogix the slot is usually 0; on Micro800 enter the IP only. - 03
Browse or add tags
Generate Tags from Device lists the controller-scoped tags. By hand:
Program:MainProgram.Counter, UDT memberMotor.Speed, arrayTank[3], DINT bitStatus.5. A whole UDT is not read as one tag. - 04
Watch live, read over OPC UA
Tick Live data in the toolbar; every tag shows its value, quality (Good / Bad / Uncertain) and timestamp. OPC UA clients read the same tags at
opc.tcp://host:48010/MergenHubunder Channel › Device › Tag.
Feature coverage
The CIP layer is shared with the OMRON NJ/NX driver; the connection type is chosen automatically from what the device supports.
By tag name
Controller-scoped and program-scoped tags (Program:Main.Tag), structure members, array elements and DINT bits.
Atomic types and STRING
BOOL, SINT, INT, DINT, LINT, REAL, LREAL and STRING (82 characters) are read and written.
Slot and hops
Device ID IP,1,slot; multiple hops and IP hops are supported. Micro800 uses the IP only.
Automatic fallback
Large Forward Open → small → unconnected messaging (Unconnected Send), falling back to what the device supports.
Tag list from the device
Controller-scoped atomic tags are listed from the device; the selected ones are added to the project in one step.
Logix + Micro800
ControlLogix, CompactLogix, GuardLogix and Micro800.